CAT 5e U/UTP cables are produced according to ISO IEC 61156-5 and TIA 568B requirements, an excellent choice to support all Class D applications like Ethernet, Fast Ethernet, Gigabit Ethernet. Category 5 Data lan cables are suitable for basic voice and data installations up to 100 MHz.
Technical Properties
Copper Weight | 17 kg/km | |
Min. Bending radius during draw in | 50 mm | |
Min. Bending radius permanently installed | 25 mm | |
Max. Tensile Strength | 100 N | |
Min. Crush Resistance | 1000 N/10 cm | |
Min. Impact | 10 Impacts | |
Installation Temperature | 0°C … + 50°C | |
Operating Temperature | -30°C … + 70°C | |
Packing | 305 / 500 m | |
Electrical Properties at 20ºC | ||
Max. Conductor Resistance | 9.5 Ω / km | |
Max. Resistance Unbalance | < 2% | |
Min. Insulation Resistance | 5000 MΩ x m | |
Mutual Capacitance | 50 pF / m | |
Max. Capacitance Unbalance | 1600 pF / km | |
Impedance at 100 MHz | 100 ± 5 Ω | |
Velocity of Propagation | 0,69 | |
Delay Skew | 45 ns / 100 m | |
Test Voltage | 1000 V | |
Operating Voltage | 125 V |
Frequency | Attenuation | NEXT | PS – NEXT | ACR | PS-ACR | ACRF | PS-ACRF | Return Loss |
(MHz) | (dB/100 m) | (dB) | (dB) | (dB/100 m) | (dB/100 m) | (dB/100 m) | (dB/100 m) | (dB) |
1 | 2 | 70 | 67 | 68 | 65 | 78 | 75 | 21 |
4 | 4 | 62 | 59 | 58 | 55 | 70 | 67 | 29 |
10 | 6 | 55 | 52 | 50 | 47 | 52 | 49 | 30 |
16 | 8 | 55 | 52 | 45 | 42 | 50 | 47 | 30 |
31 | 11 | 48 | 45 | 40 | 37 | 35 | 32 | 29 |
63 | 16 | 48 | 45 | 30 | 27 | 35 | 32 | 27 |
100 | 21 | 40 | 37 | 20 | 17 | 30 | 27 | 27 |
200 | 27 | 35 | 32 | 10 | 7 | 20 | 17 | 20 |
Product Name | Outer Sheath Material | Euro Class | Cable Weight | Flame Retardancy | Corrosive Gases | Smoke Density | Options |
U/UTP | PVC | Eca | 38 Kg/Km | EN 60332-1-2 | N/A | N/A | PVC |
U/UTP HFFR | HFFR | Dca | 39 Kg/Km | EN 60332-1-2 | EN 50267-2-3 | EN 61034-2 | HFFR |
CAT 5e U/UTP PE | PE | Fca | 34 Kg/Km | N/A | N/A | N/A | PE |