CAT 6 SF UTP Data Lan Structured Cables are produced according to ISO IEC 61156-5 and TIA 568-C.2 requirements, an excellent choice to support all Class E applications like Ethernet, Fast Ethernet, Gigabit Ethernet. Category 6 network cable are suitable for basic voice and data installations up to 250 MHz.
Copper Weight – CAT 6 SF UTP | 30,5 kg/km |
Min. Bending radius during draw in | 58 mm |
Min. Bending radius permanently installed | 29 mm |
Max. Tensile Strength | 100 N |
Min. Crush Resistance | 1000 N/10 cm |
Min. Impact | 10 Impacts |
Installation Temperature | 0°C … + 50°C |
Operating Temperature | -30°C … + 70°C |
Packing | 305 / 500 m |
Electrical Properties at 20ºC | |
Max. Conductor Resistance | 9.5 Ω / km |
Max. Resistance Unbalance | < 2% |
Min. Insulation Resistance | 5000 MΩ x m |
Mutual Capacitance | 50 pF / m |
Max. Capacitance Unbalance | 1600 pF / km |
Impedance at 100 MHz | 100 ± 5 Ω |
Velocity of Propagation | 67% |
Delay Skew | 45 ns / 100 m |
Min. TCL | Level 2 |
Coupling Attenuation | Type 1 |
Transfer Impedance | Class 2 |
Test Voltage | 1000 V |
Operating Voltage | 125 V |
Frequency | Attenuation | NEXT | PS – NEXT | ACR | PS-ACR | ACRF | PS-ACRF | Return Loss |
(MHz) | (dB/100 m) | (dB) | (dB) | (dB/100 m) | (dB/100 m) | (dB/100 m) | (dB/100 m) | (dB) |
1 | 2,0 | 83 | 80 | 85 | 82 | 83 | 80 | 25 |
4 | 3,6 | 73 | 70 | 70 | 67 | 70 | 67 | 31 |
10 | 6,0 | 73 | 70 | 65 | 62 | 60 | 57 | 30 |
100 | 19,5 | 55 | 52 | 40 | 37 | 35 | 32 | 25 |
200 | 28,5 | 50 | 47 | 25 | 22 | 30 | 27 | 22 |
250 | 32,0 | 45 | 42 | 25 | 22 | 22 | 19 | 22 |
300 | 33,0 | 40 | 37 | 15 | 12 | 20 | 17 | 22 |
400 | 39,0 | 40 | 37 | 7 | 4 | 20 | 17 | 20 |
Product Name | Outer Sheath Material | Euro Class | Cable Weight | Flame Retardancy | Corrosive Gases | Smoke Density | Options |
SF/UTP | PVC | Eca | 67 Kg/Km | EN 60332-1-2 | N/A | N/A | PVC |
Cat 6 SF/UTP HFFR | HFFR | Dca | 68 Kg/Km | EN 60332-1-2 | EN 50267-2-3 | EN 61034-2 | HFFR |
SF/UTP PE | PE | Fca | 59 Kg/Km | N/A | N/A | N/A | PE |
CAT 6 S-F/UTP (Shielded/Foil shielded Twisted Pair/ Unshielded twisted Pair) cables are a type of high-speed Ethernet cable that can support data transfer speeds of up to 10 Gbps. They are made up of four twisted pairs of copper wire, each of them individually shielded with a foil shield and the entire cable is also shielded, providing an extra layer of protection against electromagnetic interference (EMI) and radio frequency interference (RFI). This shielding helps to reduce the amount of noise on the cable and improves the overall signal quality.
One of the key features of CAT 6 S-F/UTP cables is the twisted pair design, which helps to reduce crosstalk, a phenomenon that occurs when the electromagnetic fields of one wire interfere with the signals of another wire. This twisted pair design helps to improve signal integrity and reduce data errors. The individual and overall shielding also work to reduce the amount of crosstalk and interference.
Another key feature of CAT 6 S-F/UTP cables is their high data transfer speeds. They are rated for speeds of up to 10 Gbps, which is more than twice as fast as CAT 5e cables and about the same as CAT 7 cables. This makes them suitable for high-bandwidth applications such as video streaming, gaming, and other high-speed data transfer needs.
CAT 6 S-F/UTP cables also have a higher frequency range than previous generations of Ethernet cables, they can support frequencies of up to 250 MHz, which allows for more data to be transmitted over the cable.
CAT 6 S-F/UTP cables are also backwards compatible with previous generations of Ethernet cables.